Cable Type 1:
Fiber Count | Cable Dimension mm | Cable Weight kg/km | Tensile N | Crush N/100mm | Min. Bend Radius mm | Range of Temperature | |||
Long Term | Short Term | Long Term | Short Term | Dynamic | Static | ||||
1--12 | 5 | 25 | 350 | 700 | 1000 | 2000 | 20D | 10D | --30-70℃, |
Note: 1. All the values in the table, which are for reference only, are subject to change without notice; 2. The cable dimension and weight are subject to the simplex cable of 2.0 outer diameter; 3. D is outer diameter of the round cable; |
Cable Type 2:
Fiber Count | Cable Dimension mm | Cable Weight kg/km | Tensile N | Crush N/100mm | Min. Bend Radius mm | Range of Temperature | |||
Long Term | Short Term | Long Term | Short Term | Dynamic | Static | ||||
1--12 | 7 | 45 | 400 | 800 | 1000 | 2000 | 20D | 10D | --3-70℃, |
Note: 1. All the values in the table, which are for reference only, are subject to change without notice; 2. The cable dimension and weight are subject to the simplex cable of 2.0 outer diameter; 3. D is outer diameter of the round cable; |
Item | Data |
Insertion Loss | ≤0.3dB |
Return Loss | SM/UPC≥55dB, SM/APC≥60dB, MM≥35dB |
Mechanical life | 500cycles |
Working temperature | -20°C~+70°C |
Storage temperature | -20°C~+70°C |
Tensile Data | Tensile between junction and fiber cable≥100N |